EV14-8RB-L

StrongHoldâ„¢ Ring Terminal, vinyl insulated, 16 - 14 AWG, #8 Stud Size.

Our StrongHold™ Ring Terminal is a reliable solution for secure electrical connections. Designed for 16-14 AWG wires with a #8 stud size, it ensures a snug fit for optimal performance. The vinyl insulation provides protection and durability, with a maximum operating temperature of 105°C (221°F) and a voltage rating of 600V (.6 kV). Made of high-quality copper with a tin-plated finish, this terminal guarantees efficient conductivity and corrosion resistance. The funnel entry barrel type facilitates easy wire insertion, while the RoHS compliance underscores our commitment to environmental responsibility. Trust in this product for your crimping needs, knowing it meets the highest standards of quality and performance.
AVAILABILITY
Immediate Shipment:NA
Stock Location:In Stock
Factory Stock:Call for Stock
Factory Lead:
Unit Of Measure:
Minimum/Multiple:1/1
Pricing
CALL:866.649.2022
Invalid quantity value
Product Category:
Manufacturer:Panduit
Manufacturer Part Number:Panduit EV14-8RB-L
Maximum Operating Temperature:105 °C, 221 °F
Voltage:.6 kV, 600 V
Outside Diameter:.31 in, 7.9 mm
Material:Copper
Insulation Material:Vinyl
Barrel Length:.38 in, 9.6 mm
Wire Insulation Diameter:.17 in, 4.3 mm
Barrel Type:Funnel Entry
Finish:Tin-Plated
Product Type:Ring Terminal
SKU:PANEV14-8RB-L
Supplier Product:Ring Terminals
Sub Brand:StrongHold
Overall Length mm:23.4 (mm)
Tongue Length In:0.46 (In.)
Maximum Metric Conductor Size mm:2.5 (mm²)
Tongue Width In:0.31 (In.)
Tongue Thickness In:0.03 (In.)
Color Code:Blue
Minimum Wire Insulation Diameter In:0.17 (In.)
For Use With:CT-100A, CT-200, CT-600A (CT-570CH), CT-1570, CT-2500 (CT-2570CH), CT-160, CT-260
Finish Coating:Tin-Plated
Tongue Thickness mm:0.8 (mm)
Overall Length In:0.92 (In.)
Insulation Diameter In:0.17 (In.)
Tongue Width mm:7.9 (mm)
Wire Strip Length mm:7.9 (mm)
Overall Width In:0.31 (In.)
Stud Hole Size mm:4 (mm)
Minimum Copper Conductor Size AWG STR:#16 AWG
Insulation Diameter mm:4.3 (mm)
Minimum Copper Conductor Size AWG SOL:#16 AWG
Flammability Rating:UL 587-H
Maximum Copper Conductor Size AWG STR:#14 AWG
Minimum Wire Insulation Diameter mm:4.3 (mm)
Wire Strip Length In:0.31 (In.)
Stud Hole Size In:3/20 (In.)
Tongue Length mm:11.7 (mm)
Minimum Metric Conductor Size mm:1.5 (mm²)
Overall Width mm:7.9 (mm)
Standards Met:UL Listed 587H E52164; CSA Certified LR31212
Maximum Copper Conductor Size AWG SOL:#14 AWG

Environmental Initiative Details

Environmental Initiative:RoHS
Compliant:Unknown
Date of this Information:Unknown
Notes: